1-9 A-D E-G H-M N-P Q-S T-Z

AGNIQUE CSO-30

AGNIQUE CSO-30 acts as a versatile nonionic emulsifier that helps crop protection formulations form stable and consistent mixtures with water.
AGNIQUE CSO-30 is useful for improving the distribution of hydrophobic active ingredients in agrochemical systems.
AGNIQUE CSO-30 offers a practical balance between emulsification strength, wetting performance, and formulation compatibility.

CAS Number: 61791-12-6

Synonyms: Castor oil ethoxylate, Ethoxylated castor oil, Polyethoxylated castor oil, PEG castor oil, PEG-30 castor oil, Castor oil polyoxyethylene ether, Polyoxyethylene castor oil, Nonionic castor oil surfactant, Castor oil emulsifier, Agrochemical emulsifier, Crop protection emulsifier, Agricultural formulation surfactant, Oil-in-water emulsifier, Wetting and emulsifying agent, Formulation stabilizer

AGNIQUE CSO-30 is an ethoxylated castor oil with approximately 30 EO units, used as a nonionic emulsifier in agrochemical formulations.
AGNIQUE CSO-30 helps hydrophobic active ingredients disperse more effectively in water-based spray systems and supports stable formulation behavior in EC, EW, SE, and OD products.

AGNIQUE CSO-30 can also provide wetting and adjuvancy benefits, making it useful in crop protection formulations that require emulsification, spreading, and uniform active ingredient distribution.
AGNIQUE CSO-30 with product number 30535425 and CAS number 61791-12-6.

AGNIQUE CSO-30 is a nonionic castor oil ethoxylate designed for use as an emulsifier and formulation aid in crop protection products.
AGNIQUE CSO-30 helps oil-based or poorly water-soluble active ingredients form more uniform and stable mixtures when diluted with water.

AGNIQUE CSO-30 is useful in agrochemical systems where balanced oil compatibility, water dispersibility, and emulsion stability are required.
AGNIQUE CSO-30's intermediate ethoxylation level gives it a functional balance between AGNIQUE CSO-20 and AGNIQUE CSO-40, making it suitable for formulations that need reliable emulsification, wetting, and active ingredient distribution.

Applications of AGNIQUE CSO-30:
AGNIQUE castor oil ethoxylates are biodegradable and derived from natural sources.
Typically, they are used as non-ionic emulsifiers often matched with anionic counterparts such as CaDDBS to give optimum stability in formulations such as EC, EW, SE, and OD.
In addition, AGNIQUE CSO products show wetting and adjuvancy properties.

AGNIQUE CSO-30 is a nonionic castor oil ethoxylate used as an emulsifier and formulation aid in agrochemical products.
AGNIQUE CSO-30 helps oil-based or poorly water-soluble active ingredients disperse more uniformly in water, improving emulsion stability and reducing phase separation.

AGNIQUE CSO-30 provides a balanced performance between oil compatibility and water dispersibility, making it useful in EC, EW, SE, and OD formulation systems.
AGNIQUE CSO-30 also supports wetting, spreading, and uniform active ingredient distribution in pesticide, herbicide, fungicide, and insecticide formulations.

Benefits of AGNIQUE CSO-30:
AGNIQUE CSO-30 improves emulsification in agrochemical formulations.
AGNIQUE CSO-30 helps oil-based active ingredients disperse more evenly in water.

AGNIQUE CSO-30 supports stable emulsion formation and reduces phase separation.
AGNIQUE CSO-30 provides balanced oil compatibility and water dispersibility.

AGNIQUE CSO-30 improves wetting and spreading performance during spray application.
AGNIQUE CSO-30 helps create uniform active ingredient distribution.

AGNIQUE CSO-30 can improve formulation reliability in EC, EW, SE, and OD systems.
AGNIQUE CSO-30 is useful when moderate hydrophilic-lipophilic balance is required.

Stability and Reactivity of AGNIQUE CSO-30:

Chemical stability:
AGNIQUE CSO-30 is stable under recommended storage and handling conditions.

Reactivity:
No hazardous reactions are expected under normal use conditions.

Possibility of hazardous reactions:
Dangerous reactions are not expected when the product is used properly.

Conditions to avoid:
Excessive heat, open flames, sparks, moisture, and overheated storage areas should be avoided.

Incompatible materials:
Strong oxidizing agents should be avoided.

Hazardous decomposition products:
Thermal decomposition or combustion may produce carbon oxides and irritating fumes.

Handling and Storage of AGNIQUE CSO-30:

Handling:
AGNIQUE CSO-30 should be handled according to good industrial hygiene and safety practices.

Safe handling:
Avoid contact with skin, eyes, and clothing.

Hygiene measures:
Wash hands thoroughly after handling.

Storage:
Store indoors in a dry place.

Storage conditions:
Keep containers tightly closed and avoid overheated storage rooms.

Moisture protection:
AGNIQUE CSO-30 is hygroscopic and may absorb moisture quickly, so drums should be resealed after opening.

Processing note:
If separation or solidification occurs, heat gently to 50–70 °C and homogenize before use.

First Aid Measures of AGNIQUE CSO-30:

General advice:
Remove contaminated clothing and seek medical attention if symptoms occur.

Inhalation:
Move the affected person to fresh air and keep them comfortable.

Skin contact:
Wash the affected skin thoroughly with soap and water.

Eye contact:
Rinse carefully with water for several minutes.

Ingestion:
Rinse mouth with water and seek medical advice if discomfort continues.

Medical advice:
Treat symptomatically.

Firefighting Measures of AGNIQUE CSO-30:

Suitable extinguishing media:
Use water spray, foam, dry chemical powder, or carbon dioxide.

Unsuitable extinguishing media:
Do not use a strong direct water jet if AGNIQUE CSO-30 may spread the material.

Specific fire hazards:
Combustion may produce carbon oxides and irritating decomposition products.

Protective equipment for firefighters:
Wear self-contained breathing apparatus and full protective clothing.

Further information:
Cool exposed containers with water spray if AGNIQUE CSO-30 can be done safely.

Accidental Release Measures of AGNIQUE CSO-30:

Personal precautions:
Avoid contact with skin, eyes, and clothing.

Protective equipment:
Use suitable gloves, protective clothing, and eye protection.

Environmental precautions:
Prevent release into drains, soil, surface water, or groundwater.

Containment method:
Stop the leak if AGNIQUE CSO-30 can be done safely.

Cleaning method:
Absorb with inert material such as sand, earth, or universal binder.

Disposal:
Collect in suitable labeled containers for proper disposal.

Exposure Controls / Personal Protection of AGNIQUE CSO-30:

Engineering controls:
Use adequate ventilation in the working area.

Eye protection:
Wear safety glasses or chemical goggles.

Hand protection:
Wear chemical-resistant protective gloves.

Skin protection:
Wear suitable protective clothing.

Respiratory protection:
Use respiratory protection if ventilation is insufficient or mist exposure may occur.

General hygiene measures:
Do not eat, drink, or smoke while handling the product.

Personal hygiene:
Wash hands and exposed skin after use.

Identifiers of AGNIQUE CSO-30:
Product number: PRD 30535425
Chemical description: Castor oil ethoxylate
CAS number: 61791-12-6
EC number: Not clearly specified for the commercial blend.
Structure basis: Castor oil + approximately 30 EO units.

Product Number (PRD): 30535425
Product CAS Details: 61791-12-6

Properties of AGNIQUE CSO-30:
Chemical type: Castor oil ethoxylate
Product type: Nonionic emulsifier / agrochemical surfactant
Physical form: Liquid
Active content: Approximately 100%
EO content: Approximately 30 EO units
Cloud point: Approximately 75 °C
Viscosity: Approximately 150 mPa·s at 60 °C
HLB value: Intermediate between CSO 20 and CSO 40
CAS number: 61791-12-6
Water behavior: Dispersible / emulsifiable in water

Ataman Chemicals © 2015 All Rights Reserved.